Delta EB3000 Series User Manual page 66

Elevator drive
Table of Contents

Advertisement

Terminal
Conductor
Solid
Strand
EPS
Stranded with
ferrules with plastic
sleeve
NOTE:
 Use a flathead screwdriver to tighten the wires. The head width and thickness of the flathead screwdriver are
3.5 mm and 0.6 mm.
 When wiring bare wires, ensure that they are perfectly arranged to go through the wiring holes.
Recommended dimension or models of the crimp terminals
Terminal
Wire Gauge
12 AWG
14 AWG
Crimp
16 AWG
Terminals
18 AWG
20 AWG
NOTE:
*1: Recommended specifications and models of crimping tools: DNT01-2210B or DNT01-2206B. Manufacturer:
DINKLE.
*2: Dimensions of crimp terminals are defined as follows:
Dimension A: the actual wiring space
Dimension B: the allowed depth of the terminal block.
Dimension D: the clearance of the terminal block.
Dimension W: the allowed width of the terminal block.
Stripping Length
(mm)
7–8
Models
VENDOR
VENDOR P/N
E4009
E2508
K.S.T.
E1508
E1008
E0508
A
B
Figure 4-13
Max. Wire
Min. Wire
Gauge
Gauge
4 mm
0.5 mm
2
2
(12 AWG)
(20 AWG)
Recommended Dimension *
A (MAX)
B (MAX)
15 mm
4-13
Chapter 4 WiringEB3000
Torque (±10%)
5.61 kg-cm
(4.87 lb-in.)
(0.55 Nm)
2
D (MAX)
8 mm
10 mm
Table 4-6
W (MAX)
3.5 mm
Table 4-7