 Control by PC or PLC (Computer Link):
Selects the desired mode along with the RS-485 serial port communication protocol in Pr.09-00.
 Modbus ASCII (American Standard Code for Information Interchange): Each data byte is the
combination of two ASCII characters; for example, a 1-byte data: 64 Hex, is shown as '64' in
ASCII, and consists of '6' (36 Hex) and '4' (34 Hex).
09-03
Response Delay Time
VF
Control Mode
Settings
 If the host computer does not finish the transmitting/receiving process, you can use this
parameter to set the response delay time after the AC motor drive receives communication
command as shown in the following picture.
RS-485 BUS
PC or PLC command
09-11
CAN Baud Rate
VF
Control Mode
Settings
09-04
Direct Docking Mode Only
09-99
VF
Control Mode
Settings
SVC
FOCPG
0.0–200.0 ms
Handling time
of the AC drive
SVC
FOCPG
0: 1M
1: 500k
2: 250k
3: 125k
SVC
FOCPG
Contact Delta for more information
Chapter 8 Descriptions of Parameter SettingsEB3000
FOCPM
Response Delay Time
FOCPM
FOCPM
8-09-3
Default: 2.0
Response Message
of the AC Drive
Default: 1
Default: -