Delta EB3000 Series User Manual page 245

Elevator drive
Table of Contents

Advertisement

Chapter 8 Descriptions of Parameter SettingsEB3000
Fault Code
77: STO loss 2 (StL2)
78: STO loss 3 (StL3)
85: Hardware brake over-current (Hocb)
86: Software brake over-current (Socb)
87: Brake resistor configuration error (brF)
88: Brake resistor is not connected (bro)
89: IGBT overload (oL3)
90: STO loss 4 (StL4)
91: STO loss 5 (StL5)
93: CANLift disconnection (CndL)
95: CANLift error (CnLF)
96: STO disconnection (Stod)
97: STO at running (Stor)
98: STO circuit sticking fault (StoS)
99: Ignore STO is ON (iSto)
100: Over ripple protection (orP)
Dwell
02-80
Dwell Time at Acceleration
VF
Control Mode
Settings
02-81
Dwell Frequency at Acceleration
VF
Control Mode
Settings
02-82
Dwell Time at Deceleration
VF
Control Mode
Settings
02-83
Dwell Frequency at Deceleration
VF
Control Mode
Settings
 In a heavy load situation, dwelling can temporarily stabilize the output frequency.
 Use Pr.02-80–Pr.02-83 with heavy load to prevent over-voltage or over-current.
Bit0
current
SVC
FOCPG
0.00–600.00 sec.
SVC
FOCPG
0.00–400.00 Hz
SVC
FOCPG
0.00–600.00 sec.
SVC
FOCPG
0.00–400.00 Hz
8-02-22
Bit1
Bit2
Bit3
Volt.
OL
SYS
FOCPM
Default: 0.00
FOCPM
Default: 0.00
FOCPM
Default: 0.00
FOCPM
Default: 0.00
Bit4
Bit5
Bit6
FBK
EXI
CE