2. Voltage output encoder application: Each set of input current is 5–15 mA. If input voltage
uses 12V power, connect the encoder power externally. See the PG wiring Figure 3-5 below.
EMEB-PGAB-1
VP
0V
ABZ/UVW
4.7kohm
ABZ/UVW
Figure 3-2
EMEB-PGAB-1
ABZ/UVW
4.7kohm
ABZ/UVW
Figure 3-3
EMEB-PGAB-1
ABZ/UVW
4.7kohm
ABZ/UVW
Figure 3-4
EMEB-PGAB-1
VP
0V
ABZ/UVW
4.7kohm
ABZ/UVW
Figure 3-5
Open Collector Encoder
External pull-high
resistor
Open Collector Encoder
VP
0V
Voltage Output Encoder
VP
0V
Voltage Output Encoder
VCC
ABZ/UVW
GND
3-14
VCC
External
power
ABZ/UVW
(5–12V)
GND
VCC
ABZ/UVW
GND
VCC
Internal
pull-high
resistor
ABZ/UVW
GND
External
Internal
power
pull-high
resistor
(5–12V)