Chapter 8 Descriptions of Parameter SettingsEB3000
02-03
External Terminal Output Current Level
VF
Control Mode
Settings
 When output current is ≥ Pr.02-03, it activates the multi-function output terminal (Pr.01-10–
Pr.01-15 are set to 27).
 When output current is < Pr.02-03, it activates the multi-function output terminal (Pr.01-10–
Pr.01-15 are set to 28).
Emergency Deceleration Protection
02-10
Desired Frequency Reached 1
VF
Control Mode
Settings
02-11
Desired Frequency Reached Width 1
VF
Control Mode
Settings
02-12
Desired Frequency Reached 2
VF
Control Mode
Settings
02-13
Desired Frequency Reached Width 2
VF
Control Mode
Settings
 Once the output frequency reaches the desired frequency and the corresponding multi-function
output terminal is set to 3 or 4 (Pr.01-10–Pr.01-15), this multi-function output terminal is ON.
02-14
Automatic Emergency Deceleration Level
Control Mode
Settings
SVC
FOCPG
0–100%
SVC
FOCPG
0.00–400.00 Hz
SVC
FOCPG
0.00–400.00 Hz
SVC
FOCPG
0.00–400.00 Hz
SVC
FOCPG
0.00–400.00 Hz
FOCPG
5.00–400.00 Hz
8-02-4
FOCPM
Default: 0
FOCPM
Default: 60.00 / 50.00
FOCPM
Default: 2.00
FOCPM
Default: 60.00 / 50.00
FOCPM
Default: 2.00
FOCPM
Default: 60.00