04 Protection Parameters
Pr.
Parameter Name
 04-01
Fault and Warning Action
Number of Times to Retry
 04-02
after Fault
Time Interval between
 04-03
Retries
Output of MO Terminal
 04-04
when Retrying after Fault
 04-10
STO Function Selection
Mechanical Brake
 04-11
Detection Time
Magnetic Contactor
 04-12
Detection Time
04-13
STO Timing Activation
STO Sticking Detection
 04-14
Time
 04-20
Over-slip Action
Chapter 7 Summary of Parameter SettingsEB3000
Setting Range
Bit 0 = 0: Display Lv fault and coast to
stop
Bit 0 = 1: Display Lv warn and coast to
stop
Bit 2 = 0: Software GFF protection
enabled
Bit 2 = 1: Software GFF protection
disabled
0–10 times
0.5–600.0 sec.
0: Output
1: No output
0: STO fault latched, resending RUN
command is required
1: STO warning latched, resending
RUN command is required
2: STO fault latched
3: STO warning unlatched
4: Elevator Stop timing, does not
detect STO sticking
5: Elevator Stop timing, Stoc warning
occurs when STO sticks
6: Elevator Stop timing, StoS fault
occurs when STO sticks (fault can be
cleared manually)
7: Elevator Stop timing, StL4 fault
occurs when STO sticks (fault cannot
be cleared and must be powered-on
again)
0.00–10.00 sec.
0.00–10.00 sec.
0: Triggers fault if an error occurs on
timing activation
1: Triggers warning if an error occurs
on timing activation (valid only when
using two-wire operation control)
0.0–10.0 sec.
0: Warn and keep operation
1: Warn and ramp to stop
7-17
Default
0002h
0
10.0
0
4
0.00
0.00
0
2.0
0