Delta EB3000 Series User Manual page 237

Elevator drive
Table of Contents

Advertisement

Chapter 8 Descriptions of Parameter SettingsEB3000
02-55
Direct Docking Terminal Function Enabled
Control Mode
Settings
 Related parameters: Pr.01-00–Pr.01-07 multi-function input terminal (53: terminal leveling signal
for direct docking).
 Direct docking terminal function:
When the elevator runs to the leveling area, controller sends a leveling signal to the drive to
make the drive stop within effective distance (Pr.02-53). If deceleration distance is too short, the
drive adjusts the speed according to the limit for acceleration change (Pr.02-52). Deceleration of
direct docking terminal function is calculated through Pr.00-40.
FOCPG
0000h: Disabled
0002h: Direct docking terminal function enabled
8-02-14
FOCPM
Default: 0000h

Advertisement

Table of Contents
loading

Table of Contents