Chapter 9 Warning and Fault CodesEB3000
Check the abbreviated warning code to find related information on action, reset, causes and corrective actions.
Abbreviated
ID No.
Warning Code
1
CE01
Action condition
Action time
Warning treatment
parameter
Reset method
Reset condition
Record
Cause
Incorrect communication
command from elevator
controller
Malfunction caused by
interference
Different communication
setting from the elevator
controller
Disconnection or bad
connection of the cable
Abbreviated
ID No.
Warning Code
2
CE02
Action condition
Action time
Warning treatment
parameter
Reset method
Reset condition
Record
Cause
Incorrect communication
command from elevator
controller
Malfunction caused by
interference
Different communication
setting from the elevator
controller
Disconnection or bad
connection of the cable
Display on
Warning Name
KPED-LE02
Communication error 1 Illegal function code
Action and Reset
When the function code is incorrect
Immediately act
Pr.04-60 (Default: 3)
0: Warn and keep operation
1: Fault and ramp to stop
2: Reserved
3: No action and no display
Auto
When Pr.04-60=0, cE01 is a warning and will be automatically cleared.
Manual When Pr.04-60=1, cE01 is a fault and must be reset manually.
N/A
If cE01 is a warning, it will not be recorded.
If cE01 is a fault, it will be recorded.
Check if the communication command is correct.
Verify the wiring and grounding of the communication circuit. It is recommended to
separate the communication circuit from the main circuit, or wire in 90 degree for
effective anti-interference performance.
Check if the setting for Pr.09-00–Pr.09-02 is the same as the setting for the elevator
controller.
Check the cable and replace it if necessary.
Display on
Warning Name
KPED-LE02
Communication error 2 Illegal data address
Action and Reset
When the input data address is incorrect
Immediately act
Pr.04-60 (Default: 3)
0: Warn and keep operation
1: Fault and ramp to stop
2: Reserved
3: No action and no display
Auto When Pr.04-60=0, cE02 is a warning and will be automatically cleared.
Manual When Pr.04-60=1, cE02 is a fault and must be reset manually.
N/A
If cE02 is a warning, it will not be recorded.
If cE02 is a fault, it will be recorded.
Check if the communication command is correct.
Verify the wiring and grounding of the communication circuit. It is recommended to
separate the communication circuit from the main circuit, or wire in 90 degree for
effective anti-interference performance.
Check if the setting for Pr.09-00–Pr.09-02 is the same as the setting for the elevator
controller.
Check the cable and replace it if necessary.
Corrective Actions