Delta EB3000 Series User Manual page 230

Elevator drive
Table of Contents

Advertisement

A Pr.03-02: Magnetic Contactor Contracting Delay
Time between Drive and Motor
B Pr.03-00: Brake Release Delay Time when Elevator
Starts
C Pr.03-06: DC Brake Activation Time
D Pr.02-24: Power Generation Direction Search Time
 FOCPG/PM Control Mode: In the time setting in Pr.02-24, the drive remains at zero-speed and
it is able to determine the elevator loading without performing forward/reverse run. Then the
elevator operates in the power regeneration direction (the motor is in power generating status).
Refer to the Auto-detection Timing Diagram 3 below for details.
Chapter 8 Descriptions of Parameter SettingsEB3000
Auto-detection Timing Diagram 1
Auto-detection Timing Diagram 2
E Pr.03-01: Brake Engage Delay Time when
F Pr.03-07: DC Brake Stopping Time
G Pr.03-03: Magnetic Contactor Release
8-02-7
Elevator Stops
Delay Time between Drive and
Motor

Advertisement

Table of Contents
loading