Chapter 8 Descriptions of Parameter SettingsEB3000
Multi-step Speed Parameters
00-50
Zero Step Speed Frequency
00-51
1st Step Speed Frequency
00-52
2nd Step Speed Frequency
00-53
3rd Step Speed Frequency
00-54
4th Step Speed Frequency
00-55
5th Step Speed Frequency
00-56
6th Step Speed Frequency
00-57
7th Step Speed Frequency
00-58
8th Step Speed Frequency
00-59
9th Step Speed Frequency
00-60
10th Step Speed Frequency
00-61
11th Step Speed Frequency
00-62
12th Step Speed Frequency
00-63
13th Step Speed Frequency
00-64
14th Step Speed Frequency
00-65
15th Step Speed Frequency
VF
Control Mode
Settings
 The multi-function input terminals (refer to Pr.01-00–Pr.01-07) select one of the AC motor drive
multi-step speeds (including the master frequency, in total 16 speeds). Pr.00-50–Pr.00-65
determine the speeds (frequencies) as shown above.
 When Pr.00-02 = 1, the master frequency is Pr.03-50.
 When Pr.00-02 = 3, the master frequency is Pr.00-50.
00-66
JOG Frequency
VF
Control Mode
Settings
 You can use both the external terminal JOG and the JOG key on PU. When the JOG terminal is
disabled, the AC motor drive accelerates from 0 Hz to the JOG frequency (Pr.00-66). When the
JOG terminal is enabled, the AC motor drive decelerates from the JOG frequency to zero. The
Acceleration and Deceleration time are set by these parameters (Pr.00-79, Pr.00-80). You
cannot execute the JOG command when the AC motor drive is running. When the JOG
command is running, other operation commands are invalid except the Forward and Reverse
commands and the STOP key on the digital keypad.
SVC
FOCPG
0.00–400.00 Hz
SVC
FOCPG
0.00–400.00 Hz
8-00-18
FOCPM
Default: 0.00
FOCPM
Default: 6.00