Chapter 6 Tuning ProcessEB3000
6-2-2-4 Multi-step Speed Settings
Pr.00-50–Pr.00-65 Multi-step Speed Setting
 The multi-function input terminals (refer to Pr.01-00–Pr.01-07) select one of the AC motor
drive multi-step speeds (including the master frequency, in total 16 speeds). Pr.00-50–
Pr.00-65 determine the speeds (frequencies) as shown above.
 When Pr.00-02 = 1, the master frequency is Pr.03-50.
 When Pr.00-02 = 3, the master frequency is Pr.00-50.