6.
Fault Record
Press
to see a fault
record's details.
String & Symbol Table:
!"#$%&'()*+,-./0123456789:;<=>?@ABCDEF
GHIJKLMNOPQRSTUVWXYZ[\]^_`abcdfghijklm
nopqrstuvwxyz{|}~
After you confirm the file name, press ENTER key.
To begin copying parameters until it is done.
After copying parameters is done, the keypad
automatically returns to this screen.
Press Right key to see the date of the parameters copied.
Press Right key to see the time of the parameters copied.
Able to store 6 fault codes (Keypad V1.02 and previous versions)
Able to store 30 fault codes (Keypad V1.20 and later version)
The most recent fault record shows as the first record. Choose a fault record
to see its details such as date, time, frequency, current, voltage, and
DC bus voltage)
Press Up / Down keys to select a fault record.
After selecting a fault code, press ENTER to see that
fault record's details.
Press Up / Down keys to scroll through a fault record's
details such as date, time, frequency, current, voltage,
and DC bus voltage.
Press Up / Down keys to select the next fault code.
After selecting a fault code, press ENTER to see that
fault record's details.
Press Up / Down keys to see a fault record's detail such
as date, time, frequency, current, voltage, and DC bus
voltage.
NOTE:
The AC motor drive actions are recorded and saved to the KPC-CC01. When you
remove the KPC-CC01 and connect it to another AC motor drive, the previous fault
5-11