Delta EB3000 Series User Manual page 361

Elevator drive
Table of Contents

Advertisement

Chapter 9 Warning and Fault CodesEB3000
Abbreviated
ID No.
Fault Code
34
cd2
Action condition
Action time
Fault treatment parameter N/A
Reset method
Reset condition
Record
Cause
Hardware failure
Abbreviated
ID No.
Fault Code
35
cd3
Action condition
Action time
Fault treatment parameter N/A
Reset method
Reset condition
Record
Cause
Hardware failure
Abbreviated
ID No.
Fault Code
36
Hd0
Action condition
Action time
Fault treatment parameter N/A
Reset method
Reset condition
Record
Cause
Hardware failure
Display on
Fault Name
KPED-LE02
V-phase error
Action and Reset
V-phase current level deviation is larger than 10% of the drive's rated current while
initializing
Immediately act
Cycle the power
N/A
Yes
Cycle the power.
If cd2 still occurs, return to the factory for repair.
Display on
Fault Name
KPED-LE02
W-phase error
Action and Reset
W-phase current level deviation is larger than 10% of the drive's rated current while
initializing
Immediately act
Cycle the power
N/A
Yes
Cycle the power.
If cd3 still occurs, return to the factory for repair.
Display on
Fault Name
KPED-LE02
cc hardware failure
Action and Reset
cc hardware error detected while initializing
Immediately acts when the drive detects the fault
Cycle the power
N/A
Yes
Cycle the power.
If Hd0 still occurs, return to the factory for repair.
Drive's V-phase current detection error when
powered-on
Corrective Actions
Drive's W-phase current detection error when
powered-on
Corrective Actions
Drive's cc (current clamp) hardware protection
error when powered-on
Corrective Actions
9-30
Description
Description
Description
<Go to
List of Fault
Codes>

Advertisement

Table of Contents