Delta EB3000 Series User Manual page 138

Elevator drive
Table of Contents

Advertisement

Stage
Pr.
02-03
02-02
03-60
03-06
03-30
03-31
03-33
00-71
00-90
00-91
03-52
03-54
03-11
03-13
03-14
Control
Description
Mode
VF, SVC,
External Terminal Output
FOCPG,
Current Level
FOCPM
VF, SVC,
FOCPG,
Torque Check
FOCPM
DC Brake Current Level at
VF, SVC
Start-up
VF, SVC,
FOCPG,
DC Brake Activation Time
FOCPM
Zero Speed Position
FOCPM
Control Gain (P)
Zero Speed Position
FOCPM
Control Holding Time
Zero Speed Position
FOCPM
Control Activation Mode
Selection
VF, SVC,
FOCPG,
Accel. Time 1
FOCPM
VF, SVC,
S-curve for Acceleration
FOCPG,
Begin Time S1
FOCPM
VF, SVC,
S-curve for Acceleration
FOCPG,
Arrival Time S2
FOCPM
Second Output Voltage
VF
Setting
Third Output Voltage
VF
Setting
FOCPG,
Mechanical Inertial Ratio
FOCPM
FOCPG,
Low Speed Bandwidth
FOCPM
FOCPG,
High Speed Bandwidth
FOCPM
0–100% (drive's rated current)
0: Disable
1: Enable
0–100% (drive's rated current)
0.0–60.0 sec.
0.00–655.00%
0.000–65.535 sec.
0: After the brake release set
in Pr.03-00
1: After the brake signal input
(Pr.01-00–Pr.01-07 is set to
42)
0.00–600.00 sec.
0.00–25.00 sec.
0.00–25.00 sec.
230V models: 0.0–255.0 V
460V models: 0.0–510.0 V
230V models: 0.0–255.0 V
460V models: 0.0–510.0 V
1–300%
1–40 Hz
1–40 Hz
6-21
Chapter 6 Tuning ProcessEB3000
Settings
Default
80.00
0.250
0
0
0
0.7
0
3.00
1.00
1.00
5.0
10.0
5.0
10.0
40
10
10

Advertisement

Table of Contents
loading

Table of Contents