6-2-2-3 Elevator Related Parameters
Pr.00-40 Elevator Speed
Elevator speed (m/sec. = m/min. ÷ 60)
Pr.00-45 Motor Current at Acceleration
The maximum motor current measured when the elevator is tuning in automatic mode.
Pr.03-11 Mechanical Inertial Ratio
You can calculate the load inertia according to the settings of motor parameters, Pr.00-45
Motor Current at Acceleration and Pr.00-46 Carriage Acceleration. You can use this
parameter to adjust the mechanical inertia ratio.
Mechanical inertia reference value (%):
Load / Motor
Without load
With load
IM
PM
40
10
80–120
40
6-15
Chapter 6 Tuning ProcessEB3000