Delta EB3000 Series User Manual page 228

Elevator drive
Table of Contents

Advertisement

 When MI is set to 56, the system monitors the current speed. If the speed is higher than Pr.02-
14, the drive decelerates to Pr.00-94 speed according to Pr.02-15 deceleration time.
02-15
Deceleration Time for Emergency Deceleration
Control Mode
Settings
 When MI=55 function is triggered, the drive decelerates to Pr.00-94 speed according to Pr.02-15
deceleration time, as shown in the figure below.
02-16
Emergency Stop (EF) & Forced Stop
VF
Control Mode
Settings
 When the multi-function input terminal is set to 10 or 18 and is ON, the drive operates according
to this parameter setting.
FOCPG
0.00–600.00 sec.
SVC
FOCPG
0: Coast to stop
1: According to deceleration Time 1
2: According to deceleration Time 2
3: According to deceleration Time 3
4: According to deceleration Time 4
5: According to Pr.00-82
Chapter 8 Descriptions of Parameter SettingsEB3000
FOCPM
FOCPM
8-02-5
Default: 2.00
Default: 0

Advertisement