4. Line driver output encoder application: Each set of input current is 5–15 mA. If input voltage uses
12V power, connect the encoder power externally. See the PG wiring Figure 3-22 below.
NOTE:
1. Verify that the SW1 is set to the correct output voltage before powering ON.
2. Keep the motor drive wiring away from any high voltage lines to avoid interference.
EMEB-PGABD-1
ABZ/UVW
4.7kohm
ABZ/UVW
Figure 3-21
EMEB-PGABD-1
VP
ABZ/UVW
4.7kohm
ABZ/UVW
0V
Figure 3-22
Line Driver Encoder
VP
0V
Line Driver Encoder
VCC
ABZ/UVW
ABZ/UVW
GND
3-23
Chapter 3 Option CardsEB3000
VCC
ABZ/UVW
ABZ/UVW
GND
External
power
(5–12V)