In PP (Profile Position) mode, when target position received by the drive is smaller than Pr.05-
16, fault code CnLF occurs.
05-17
Position Unit (Pulse)
VF
Control Mode
Settings
In PP (Profile Position) mode, shaft encoder passes through a few pulses within Pr.05-18
distance, which is used for unit conversion of PP mode. This parameter also refers to CANLift
object 641Fh-01 in CANLift protocol.
05-18
Position Unit (mm)
VF
Control Mode
Settings
In PP (Profile Position) mode, sets the length of shaft encoder, which is used for unit conversion
of PP mode. This parameter also refers to CANLift object 641Fh-02 in CANLift protocol.
05-19
Velocity Window Range
VF
Control Mode
Settings
Sets the velocity window range in CANLift PV mode. When this setting is finished, object 6435h-
01 will become this setting value.
05-20
Velocity Window Time
VF
Control Mode
Settings
Sets the detection time for velocity window in CANLift PV mode. When this setting is finished,
object 6435h-02 will become this setting value.
05-21
Velocity Threshold Range
VF
Control Mode
Settings
Sets the velocity threshold range in CANLift PV mode. When this setting is finished, object
6436h-01 will become this setting value.
05-22
Velocity Threshold Time
VF
Control Mode
Settings
Sets the detection time for velocity threshold in CANLift PV mode. When this setting is finished,
object 6463h-02 will become this setting value.
SVC
FOCPG
0–65535
SVC
FOCPG
0–65535
SVC
FOCPG
0–1000 mm/s
SVC
FOCPG
0–1000 m/s
SVC
FOCPG
0–1000 mm/s
SVC
FOCPG
0–1000 m/s
Chapter 8 Descriptions of Parameter SettingsEB3000
FOCPM
FOCPM
FOCPM
FOCPM
FOCPM
FOCPM
8-05-3
Default: 10000
Default: 4473
Default: 10
Default: 100
Default: 10
Default: 100