Chapter 8 Descriptions of Parameter SettingsEB3000
08 Data Logger Parameters
DataLog
08-00
Usage of Logger RAM
VF
Control Mode
 Records the number of channels, data length, and time to calculate the usage of logger RAM. A
maximum of logger RAM is 492k bytes. If the usage of logger RAM exceeds 100%, number of
channels / recorded time / sampling cycle need to be adjusted to be smaller than 100%.
 Example:
If the number of channels = 2, data recorded = one word, recorded time = 20 sec., sampling
cycle = 1 ms, then the usage of logger RAM is 17% [=2 × 20 × 1000 × 2(Byte) = 80k byte].
08-01
Records of Number of Channels
VF
Control Mode
Settings
 A maximum of 20 channels (20 sets of data) is provided for data logger.
08-02
Time Recorded before Trigger
VF
Control Mode
Settings
 Sets the time that records data before triggering logic.
08-03
Time Recorded after Trigger
VF
Control Mode
Settings
 Sets the time that records data after triggering logic.
08-04
Sampling Cycle
VF
Control Mode
Settings
 When Pr.08-04 = 3 / 4 / 5, it does not monitor using the common 29 sets of variables, but
monitor other variables by entering hexadecimal RAM address directly into the source of
channel.
08-05
Source of Channel 1
08-08
Source of Channel 2
08-11
Source of Channel 3
SVC
FOCPG
SVC
FOCPG
0–20
SVC
FOCPG
0–20 sec.
SVC
FOCPG
0–20 sec.
SVC
FOCPG
0: Normal 1 ms
1: Normal 500 μs
2: Normal 200 μs
3: Advanced 1 ms
4: Advanced 500 μs
5: Advanced 200 μs
: You can set this parameter during operation.
FOCPM
FOCPM
FOCPM
FOCPM
FOCPM
8-08-2
Default: Read only
Default: 0
Default: 1
Default: 1
Default: 0