Delta EB3000 Series User Manual page 254

Elevator drive
Table of Contents

Advertisement

 Sets this parameter when elevator jerk at start-up or carriage inversion occurs. In principle, the
holding time cannot exceed the time when frequency starts output.
03-32
Zero Speed Position Control Low Pass Filter Time
Control Mode
Settings
03-33
Zero Speed Position Control Activation Mode Selection
Control Mode
Settings
 When Pr.03-33 = 0, use the zero speed control with Pr.03-00 (see Pr.03-03 for detailed
descriptions).
03-34
Elevator Starting (Zero Speed Gain P)
VF
Control Mode
Settings
03-35
Elevator Starting (Zero Speed Integral I)
VF
Control Mode
Settings
0.000–65.535 sec.
0: After the brake release set in Pr.03-00
1: After the brake signal input (Pr.01-00–Pr.01-07 is set to 42)
SVC
FOCPG
0.0–1000.0%
SVC
FOCPG
0.000–10.000 sec.
Chapter 8 Descriptions of Parameter SettingsEB3000
FOCPM
FOCPM
FOCPM
FOCPM
8-03-7
Default: 0.004
Default: 0
Default: 100.0
Default: 0.100