Delta EB3000 Series User Manual page 482

Elevator drive
Table of Contents

Advertisement

Status monitor read only (22xx): communication station address is Pr.09-00 setting value
Function Name
Output current
Output frequency
DC bus voltage
Output voltage
Power factor angle
Power output
Actual motor speed
Output torque
Feedback position
AUI1 analog input
ACI analog input
AUI2 analog input
IGBT temperature
Drive capacitance
temperature
Digital input status
Digital output status
Multi-step speed
The corresponding
CPU pin status of
digital input
The corresponding
CPU pin status of
digital output
Overload counter
GFF
DC bus voltage ripples
User page displays
Control mode
Attribute
Modbus
(Function
Address
Code)
2200H
R (03H) Displays drive's output current
2202H
R (03H) Actual motor frequency (XXX.XX Hz)
2203H
R (03H) Drive's DC bus voltage (XXX.X V)
2204H
R (03H) Drive's U, V, W output value (XXX.X V)
2205H
R (03H) Drive's output power factor angle (XXX.X°)
2206xH
R (03H) Displays output power of U, V, W (XXXX.X kW)
Displays motor speed in rpm estimated by the drive or by
2207H
R (03H)
encoder feedback (XXXXX rpm)
Displays positive/negative output torque in %, estimated by
2208H
R (03H)
the drive (XXX.X %)
2209H
R (03H) Displays PG feedback
Displays signal of AUI1 analog input terminal, -10–10 V
220BH
R (03H)
corresponds to -100.00–100.00%
Displays signal of ACI analog input terminal, 4–20 mA / 0–10
220CH
R (03H)
V corresponds to 0.00–100.00%
Displays signal of AUI2 analog input terminal, -10–10 V
220DH
R (03H)
corresponds to -100.00–100.00%
220EH
R (03H) IGBT temperature of drive power module (XXX.X°C)
220FH
R (03H) Drive's capacitance temperature (XXX.X°C)
The status of digital input (ON / OFF), see Pr.07-41 Example 1
2210H
R (03H)
for details.
The status of digital output (ON / OFF), see Pr.07-41 Example
2211H
R (03H)
2 for details.
Drive's current running speed step given by multi-step speed
2212H
R (03H)
command
The corresponding CPU pin status of digital input, see Pr.07-
2213H
R (03H)
41 Example 1 for details.
The corresponding CPU pin status of digital output, see Pr.07-
2214H
R (03H)
41 Example 2 for details.
2219H
R (03H) Times of overload counter (the maximum is 64050)
221AH
R (03H) Ground fault (GFF) current short to ground value (XXX.XX%)
221BH
R (03H) DC bus voltage ripples (XXX.X V)
221EH
R (03H) Displays of user-defined values
2223H
R (03H) Drive's control mode (0: speed mode / 1: torque mode)
Appendix B. Modbus ProtocolEB3000
Description
B-13

Advertisement

Table of Contents
loading

Table of Contents