Delta EB3000 Series User Manual page 203

Elevator drive
Table of Contents

Advertisement

Chapter 8 Descriptions of Parameter SettingsEB3000
00-81
Switch Frequency between First and Fourth Accel./Decel.
VF
Control Mode
Settings
 Determines the frequency for the transition from acceleration and deceleration time 1 to
acceleration and deceleration time 4. You can also enable the transition from acceleration or
deceleration time 1 to acceleration and deceleration time 4 with the external terminals (Pr.01-
00–Pr.01-07). The external terminal has priority over Pr.00-81.
00-82
Deceleration Time when Operating without RUN Command
VF
Control Mode
Settings
 The AC motor drive stops according to this parameter when cancelling the RUN command.
Refer to the figure in the description for Pr.00-94 for details.
S-curve Parameters
00-90
S-curve for Acceleration Begin Time S1
00-91
S-curve for Acceleration Arrival Time S2
00-92
S-curve for Deceleration Begin Time S3
00-93
S-curve for Deceleration Arrival Time S4
00-95
S-curve for Deceleration Arrival Time S5
VF
Control Mode
Settings
00-94
Switch Frequency for S4 to S5
VF
Control Mode
Settings
 Using an S-curve gives the smoothest transition between speed changes. The acceleration and
deceleration curve adjusts the acceleration and deceleration S-curve. When enabled, the motor
drive produces a different acceleration and deceleration curve according to the acceleration and
deceleration time.
SVC
FOCPG
0.00–400.00 Hz
SVC
FOCPG
0.00–600.00 sec.
SVC
FOCPG
0.00–25.00 sec.
SVC
FOCPG
0.00–400.00 Hz
8-00-22
FOCPM
Default: 0.00
FOCPM
Default: 2.00
FOCPM
Default: 1.00
FOCPM
Default: 0.00

Advertisement

Table of Contents
loading