Delta EB3000 Series User Manual page 160

Elevator drive
Table of Contents

Advertisement

Pr.
Parameter Name
Electronic Thermal
 04-54
Characteristic
IGBT Overheat Warning
 04-55
(oH1)
COM Transmission Fault
 04-60
Treatment
 04-61
Time-out Detection
Communication (RJ45)
 04-62
Fault Treatment
Communication (RJ45)
 04-63
Time-out
Communication (RJ45)
 04-64
Delay Time
Encoder Feedback
 04-70
Signal Fault Action
(PGF1, PGF2)
Encoder Feedback
 04-71
Signal Fault Detection
Time
Encoder Stall and Slip
Error Action (PGF3,
 04-72
PGF4) (maximum output
frequency Pr.03-50 =
100%)
Encoder Stall Level
 04-73
(PGF3)
Encoder Stall Detection
Time (maximum output
 04-74
frequency Pr.03-50 =
100%)
Encoder Slip Range
(PGF4) (maximum output
 04-75
frequency Pr.03-50 =
100%)
Encoder Slip Detection
Time (maximum output
 04-76
frequency Pr.03-
50=100%)
Chapter 7 Summary of Parameter SettingsEB3000
Setting Range
30.0–600.0 sec.
0.0–110.0°C
0: Warn and keep operation
1: Fault and ramp to stop
2: Reserved
3: No action and no display
0.0–100.0 sec.
0.0: Disable
0: Warn and keep operation
1: Fault and ramp to stop
2: Reserved
3: No action and no display
0.0–100.0
0.0–200.0
0: Warn and keep operation
1: Fault and ramp to stop
2: Fault and stop operation
0.0–10.0 sec.
0: Warn and keep operation
1: Fault and ramp to stop
2: Fault and stop operation
0–120%
0: Disable
0.0–2.0 sec.
0–50%
0: Disable
0.0–10.0 sec.
7-19
Default
60.0
varies
with
drive
identity
code
3
0.0
3
0.0
2.0
2
1.0
2
115
0.1
50
0.5

Advertisement

Table of Contents
loading