 Pr.04-10=0: STO fault latched, resending RUN command is required. If STO is ON in any
condition and a fault occurs, it does not reset until STO is back to normal and use a RESET
command or power-on again after resending the RUN command.
 Pr.04-10=1: STO warning latched, resending RUN command is required. If STO is ON in any
condition and a warning occurs, it does not reset until STO is back to normal and resend the
RUN command.
 Pr.04-10=2: STO fault latched. If STO is ON in any condition and a fault occurs, it does not reset
until STO is back to normal and use a RESET command or power-on again.
 Pr.04-10=3: STO warning unlatched. If STO is ON in any condition and a warning occurs, it
automatically resets when STO is back to normal.
 Pr.04-10=4 / 5 / 6 / 7: When FWD/REV command is ON and STO circuit is OFF for more than
10 ms, and when Pr.00-03=1 and Pr.04-13=1, STO will be OFF and then Stob warning occurs.
When FWD/REV command is OFF and STO circuit is ON, Stob warning will be automatically
cleared. Once Stob warning is cleared, the drive starts to run when FWD/REV command and
STO circuit are both ON. When Pr.00-03=2 / 3 / 6 and Pr.04-13=1, Stod fault occurs. Stod fault
can be reset only when RUN command is removed. If there is no warning or fault that
specifically requires to give RUN command again, the drive normally will start to run when
FWD/REV command and STO circuit are both ON after warning/fault is cleared.
 Pr.04-10=4 / 5 / 6 / 7: If STO circuit is OFF while drive outputs, STO circuit will be OFF in
advance and then Stor fault occurs. This fault will be automatically cleared after 5 seconds.
 STO function selection comparison table:
STL1
STL2
STL3
04-10
Fault
Fault
Fault
(STO
Function
Hardware failure
Selection)
0
1
2
3
4
5
6
7
NOTE:
*
1
: This function is set to be enabled by default, and can be disabled through MI=57 (STO signal check) settings.
*
: To display Fault or Warning depends on Pr.04-13.
2
 For more information on the timing diagram, see Section 4-9 Drive's STO Function.
4: Elevator Stop timing, does not detect STO sticking
5: Elevator Stop timing, Stoc warning occurs when STO sticks
6: Elevator Stop timing, StoS fault occurs when STO sticks (fault can be
cleared manually)
7: Elevator Stop timing, StL4 fault occurs when STO sticks (fault cannot be
cleared and must be powered-on again)
STL5
Stoo
StoA
Fault
Fault
Warning
24-hour
STO circuit OFF
sticking
✓*
1
✓*
1
✓*
1
✓*
1
✓*
1
✓*
1
✓*
1
✓*
1
Stoc
StoS
STL4
Warning
Fault
Fault
STO circuit sticks. Must cycle the
power to clear the fault (STL4).
8-04-4
Stod Fault
Stor Fault
(Pr.04-13=0)
STO circuit is
STO circuit should be ON but is
OFF during
not ON
drive output
✓*
2
✓*
2
✓*
2
✓*
2
Stob Warning
(Pr.04-13=1)
✓*
2
✓*
2
✓*
2
✓*
2