Delta EB3000 Series User Manual page 148

Elevator drive
Table of Contents

Advertisement

Pr.
Parameter Name
Digital Input
 01-08
Response Time
FWD/REV Terminal
 01-09
Contact Action
Multi-function Output
 01-10
1: RA1, RB1, RC1
(Relay 1)
Multi-function Output
 01-11
2: RA2, RC2 (Relay 2)
Multi-function Output
 01-12
3: RA3, RC3 (Relay 3)
Multi-function Output
 01-13
4: RA4, RC4 (Relay 4)
Multi-function Output
 01-14
5: MO1
Multi-function Output
 01-15
6: MO2
Setting Range
40: Enable drive function
41: Magnetic contactor detection
42: Mechanical brake 1
43: EPS function (Emergency Power
System)
44: Mechanical brake 2
45–51: Direct docking mode only
53: Terminal leveling signal for direct
docking
54: Power failure signal
55: Manual emergency deceleration
56: Automatic emergency deceleration
57: STO signal check
0.001–30.000 sec.
0: Disable
1: FWD inversed
2: REV inversed
3: FWD and REV inversed
0: No function
1: Indication during operation
2: Operation speed reached
3: Desired frequency 1 reached (Pr.02-10,
Pr.02-11)
4: Desired frequency 2 reached (Pr.02-12,
Pr.02-13)
5: Zero Speed (Frequency command)
6: Zero speed with stop (Frequency
command)
7: Over-torque (OT1) (Pr.04-40–04-42)
8: Reserved
9: Drive is ready
10: User-defined low-voltage detection
(LV)
11: Fault indication
12: Mechanical brake release (Pr.03-00,
Pr.03-01, Pr.02-02)
13: IGBT overheat warning (oH1)
14: Brake transistor signal
15: Motor-controlled magnetic contactor
output
7-7
Chapter 7 Summary of Parameter SettingsEB3000
Default
0.005
0
0
0
0
0
0
0

Advertisement

Table of Contents
loading

Table of Contents