Chapter 8 Descriptions of Parameter SettingsEB3000
03 Comfort Adjustment Parameters
Delay Time
03-00
Brake Release Delay Time when Elevator Starts
VF
Control Mode
Settings
03-01
Brake Engage Delay Time when Elevator Stops
VF
Control Mode
Settings
 When the AC motor drive runs and after the delay time in Pr.03-00, the corresponding multi-
function output terminal (12: mechanical brake release) is ON.
 When the AC motor drive stops and after the delay time in Pr.03-01, the corresponding multi-
function output terminal (12: mechanical brake release) is OFF.
 Use this function with the DC brake function.
03-02
Magnetic Contactor Contracting Delay Time between Drive and Motor
03-03
Magnetic Contactor Release Delay Time between Drive and Motor
VF
Control Mode
Settings
 After running, use these parameters with multifunction input terminal setting 40 (Enable drive
function), and multifunction output terminal setting 15 (motor-controlled magnetic contactor
output). When the multifunction output terminals are ON, the drive starts outputting after the
delay time in Pr.03-02. When the drive stops outputting, multifunction output terminals release
after the delay time in Pr.03-03.
SVC
FOCPG
0.000–65.000 sec.
SVC
FOCPG
0.000–65.000 sec.
SVC
FOCPG
0.010–65.000 sec.
: You can set this parameter during operation.
FOCPM
FOCPM
FOCPM
8-03-2
Default: 0.250
Default: 0.250
Default: 0.200