Method 2: After rebooting, the password function is restored.
Method 3: Entering a non-password value into Pr.07-20.
Password Decode Flow Chart
07-22
Times of Drive Service
VF
Control Mode
 Sets service times of the drive before enabling drive service. If service times=0, service time-out
occurs.
07-23
Drive Service Setting
VF
Control Mode
Settings
PWM (Pulse Width Modulation)
07-30
Carrier Frequency
VF
Control Mode
Settings
 If the drive is in FOCPM control mode (Pr.00-01=3), the setting range of Pr.07-30 will be 4–15
kHz.
 Determines the PWM carrier frequency for the AC motor drive.
SVC
FOCPG
SVC
FOCPG
0: Disable
1: Enable
SVC
FOCPG
2–15 kHz
Chapter 8 Descriptions of Parameter SettingsEB3000
FOCPM
FOCPM
FOCPM
8-07-5
Default: Read only
Default: Read only
Default: 12