10
ovS
Action condition
Action time
Fault treatment parameter Stops output immediately, and coasts to stop.
Reset method
Reset condition
Record
Cause
Power voltage changes
Hardware failure in voltage
detection
Malfunction caused by
interference
Abbreviated
ID No.
Fault Code
11
LvA
Action condition
Action time
Fault treatment parameter Stops output immediately, and coasts to stop.
Reset method
Reset condition
Record
Cause
Power voltage changes
The load is too large
Acceleration time is too
short
Abbreviated
ID No.
Fault Code
12
Lvd
Action condition
Action time
Fault treatment parameter Stops output immediately, and coasts to stop.
Reset method
Reset condition
Record
Cause
Power voltage changes
Sudden load
Display on
Fault Name
KPED-LE02
Over-voltage at stop
Action and Reset
DC bus is higher than 410V / 820V
Immediately act
Use Pr.04-02 to set to reset automatically or manually
Resets when DC bus is lower than 369V / 738V
Yes
Check if the input voltage is within the rated drive input voltage range, and check for
possible voltage spikes.
Check if other fault codes such as Hd2 occurs after cycling the power. If yes, return to
the factory for repair.
Verify the wiring of the control circuit and the wiring/grounding of the main circuit to
prevent interference.
Display on
Fault Name
KPED-LE02
Low voltage during
acceleration
Action and Reset
DC bus voltage level (Pr.04-30)
Immediately act
Use Pr.04-01 or Pr.04-02 to set to reset automatically or manually
230 models Resets when DC bus voltage is higher than Pr.04-30 + 30 V
for 50 ms
460 models
Pr.04-01 (Default: 0)
When Bit 0 = 0 (Display Lv fault and coast to stop), LvA is a fault and will be recorded.
When Bit 0 = 1 (Display Lv warn and coast to stop), LvA is a warning and will not be
recorded.
Adjust the input voltage to the power range of the drive
Reduce the load.
Increase the drive capacity.
If the DC bus low voltage of the drive is caused by the heavy door weight, increase the
acceleration time.
Display on
Fault Name
KPED-LE02
Low voltage during
deceleration
Action and Reset
DC bus voltage level (Pr.04-30)
Immediately act
Use Pr.04-01 or Pr.04-02 to set to reset automatically or manually
230 models Resets when DC bus voltage is higher than Pr.04-30 + 30 V
for 50 ms
460 models
Pr.04-01 (Default: 0)
When Bit 0 = 0 (Display Lv fault and coast to stop), Lvd is a fault and will be recorded.
When Bit 0 = 1 (Display Lv warn and coast to stop), Lvd is a warning and will not be
recorded.
Adjust the input voltage to the power range of the drive
Reduce the load.
Increase the drive capacity.
Chapter 9 Warning and Fault CodesEB3000
DC bus over-voltage at stop
Corrective Actions
DC bus voltage is lower than Pr.04-30 (low
voltage level) setting value during acceleration
Corrective Actions
DC bus voltage is lower than Pr.04-30 (low
voltage level) setting value during deceleration
Corrective Actions
9-23