Delta EB3000 Series User Manual page 285

Elevator drive
Table of Contents

Advertisement

Chapter 8 Descriptions of Parameter SettingsEB3000
07 System Parameters
Drive Information
07-00
AC Motor Drive Identity Code
VF
Control Mode
07-01
AC Motor Drive Rated Current Display
VF
Control Mode
 Pr.07-00 displays the AC motor drive identity code. The capacity, rated current, rated voltage
and the maximum carrier frequency relate to the identity code. Use the following table to check
how the AC motor drive rated current, rated voltage, and maximum carrier frequency
correspond to the identity code.
 Pr.07-01 displays the AC motor drive rated current. By reading this parameter, you can check if
the AC motor drive is correct.
Power (kW)
Horsepower (HP)
Motor Drive ID Code (Pr.07-00)
Rated Output Current (A)
Range of the Carrier
Frequency (kHz)
Rated Max. Output Carrier
Frequency (kHz)
07-02
Software Version
VF
Control Mode
07-03
Date Code Y.WKD
VF
Control Mode
 Displays the year / week / day that the program of this firmware version is completed. For
example, 21.321 indicates that the program is completed on the first day of the 32th week in
year 2021.
07-04
Extension Card Firmware Version
VF
Control Mode
 If it displays 88.88, it means there is no firmware version for the extension card. Currently, only
option card EMEB-PGSED-1 displays firmware version.
07-05
Power Board Firmware Version
VF
Control Mode
 Displays the firmware version of power board MCU
SVC
FOCPG
FOCPM
SVC
FOCPG
FOCPM
230V Models
2.2*
3.7*
3
5
306
307
11
18
2–15
2–15
10
10
SVC
FOCPG
FOCPM
SVC
FOCPG
FOCPM
SVC
FOCPG
FOCPM
SVC
FOCPG
FOCPM
8-07-2
: You can set this parameter during operation.
Default: Read only
Default: Read only
460V Models
4.0
5.5
7.5
5
7.5
10
407
408
409
10
15
18.5
2–15
2–15
2–15
10
8
8
Default: Read only
Default: Read only
Default: Read only
Default: Read only
11
15
18.5
15
20
25
410
411
412
27
33
39
2–15
2–15
2–15
8
8
8
*: Single-phase models.