Steel Rope Life Inspection
02-60
Permanent Operation Direction Count (H)
VF
Control Mode
02-61
Permanent Operation Direction Count (L)
VF
Control Mode
02-62
Single Operation Direction Count (H)
VF
Control Mode
02-63
Single Operation Direction Count (L)
VF
Control Mode
02-64
Number of Times for Single Operation Reset
VF
Control Mode
02-65
Number of Times for Operation Direction
VF
Control Mode
Settings
02-66
Function Selection for Operation Times
VF
Control Mode
Settings
 When you set Pr.02-66 to 0:
Disable the operation direction count function and clear parameters (Pr.02-62, Pr.02-63, and
Pr.02-65), and add one time to the number of times for single operation reset (Pr.02-64).
 When you set Pr.02-66 to 1:
Enable the operation direction count function and add one time to the permanent operation
direction count and single operation direction count whenever the operation direction changes.
If the single operation direction count is larger than Pr.02-65, it displays a SERV warning and
continues operation.
 When you set Pr.02-66 to 2:
Enable the operation direction count function and add one time to the permanent operation
direction count and single operation direction count whenever the operation direction changes.
If the single operation direction count is larger than Pr.02-65, it displays a SERV fault and
decelerates to stop.
Fault Output
02-70
Fault Output Setting Method
VF
Control Mode
Settings
SVC
FOCPG
SVC
FOCPG
SVC
FOCPG
SVC
FOCPG
SVC
FOCPG
SVC
FOCPG
0.00–200.00 k
SVC
FOCPG
0–2
SVC
FOCPG
0: According to settings in Pr.02-71–Pr.02-74
1: According to the binary setting
8-02-17
Chapter 8 Descriptions of Parameter SettingsEB3000
FOCPM
Default: Read only
FOCPM
Default: Read only
FOCPM
Default: Read only
FOCPM
Default: Read only
FOCPM
Default: Read only
FOCPM
Default: 2.00
FOCPM
Default: 0
FOCPM
Default: 0