Delta EB3000 Series User Manual page 291

Elevator drive
Table of Contents

Advertisement

Chapter 8 Descriptions of Parameter SettingsEB3000
3: Display the drive's DC bus voltage (v) (Unit: V
)
DC
4: Display the terminals U, V, and W output voltage of the drive (E) (Unit:
V
)
AC
5: Display the terminals U, V, and W output power factor angle to the motor
(n) (Unit: deg)
6: Display the terminals U, V, and W output power to the motor (P) (Unit: kW)
7: Display the actual motor speed in rpm (r) (Unit: rpm)
8: Display the drive's estimated output torque in %; the motor's rated torque
is 100% (t) (Unit: %)
9: Display the PG feedback (G) (See Pr.00-20 and Pr.00-21)
10: Display the electrical angle of drive output (d) (Unit: deg)
11: Display the AUI1 analog input terminal signal (1.) (Unit: %)
12: Display ACI1 (Unit: %)
13: Display the AUI2 analog input terminal signal (Unit: %)
14: Reserved
15: Display the IGBT temperature (T) (Unit: °C)
16: Display digital input status ON/OFF (i)
17: Display digital output status ON/OFF (o)
18: Display the step speed of multi-step speed that is executing (S)
19: The corresponding CPU digital input pin status (i.)
20: The corresponding CPU digital output pin status (o.)
21–23: Reserved
24: Output AC voltage when malfunction occurred (E) (Unit: V
)
AC
25: Output DC voltage when malfunction occurred (v) (Unit: V
)
DC
26: Motor frequency when malfunction occurred (H) (Unit: Hz)
27: Output current when malfunction occurred (A) (Unit: Amp)
28: Output frequency when malfunction occurred (F) (Unit: Hz)
29: Frequency command when malfunction occurred (F) (Unit: Hz)
30: Output power when malfunction occurred (P) (Unit: kW)
31: Output torque when malfunction occurred (t) (Unit: %)
32: Input terminal status when malfunction occurred (i)
33: Output terminal status when malfunction occurred (o)
34: Reserved
35: 24-hour detection for STO status
36: Reserved
37: Reserved
38: Reserved
 This parameter displays the content on the built-in keyboard panel KPED-LE02 user-defined
page. Use this parameter to get the AC motor drive's status.
 Example 1:
8-07-8