Delta EB3000 Series User Manual page 145

Elevator drive
Table of Contents

Advertisement

Chapter 7 Summary of Parameter SettingsEB3000
Pr.
Parameter Name
orientation
00-30
Motor Auto-tuning
00-31
IM/PM Rs
00-32
IM Rr
00-33
IM Lm / PM Ld
00-34
IM Lx / PM Lq
00-35
Back Electromotive Force
Offset Angle between
00-36
Magnetic Pole and PG
Origin
 00-40
Elevator Speed
00-41
Elevator Rated Load
 00-42
Traction Sheave Diameter
 00-43
Gear Ratio
 00-44
Suspension Ratio
Motor Current at
 00-45
Acceleration
 00-46
Carriage Acceleration
 00-50
Zero Step Speed Frequency
 00-51
1st Step Speed Frequency
 00-52
2nd Step Speed Frequency
 00-53
3rd Step Speed Frequency
 00-54
4th Step Speed Frequency
 00-55
5th Step Speed Frequency
Setting Range
1: Six-pulse positioning
0: No function
3: IM dynamic test (Rs, Rr, Lm, Lx,
no-load current) [motor runs]
4: IM static test (Rs, Rr, Lm, Lx)
[motor does not run]
6: PM Only for an unloaded motor;
auto-measures the angle between
magnetic pole and PG origin (Pr.00-
36)
7: SPM static test (Rs, Ld, Lq,
BEMF) (suggested to lock the
brake)
8: PM auto-measures the angle
between magnetic pole and PG
origin (Pr.00-36)
9: IPM / SPM dynamic test (Rs, Ld,
Lq, BEMF)
10: IPM / SPM static test (Rs, Ld,
Lq, BEMF) (suggested to lock the
brake)
0.000–65.535 Ω
0.000–65.535 Ω
0.0–6553.5 mH
0.0–6553.5 mH
0.0–6553.5 Vrms
0.0–360.0°
0.10–4.00 m/s
400–4000 kg
100–2000 mm
1.00–100.00
0 = 1: 1
1 = 2: 1
2 = 4: 1
3 = 8: 1
50–200%
0.20–2.00 m/s
2
0.00–400.00 Hz
0.00–400.00 Hz
0.00–400.00 Hz
0.00–400.00 Hz
0.00–400.00 Hz
0.00–400.00 Hz
7-4
Default
0
0.000
0.000
0.0
0.0
0.0
360.0
1.00
800
400
1.00
1
150
0.75
0.00
0.00
0.00
0.00
0.00
0.00