After both Enable Drive function signal and MO15 output, the drive starts to count Pr.03-02.
02-01
Two-wire Operation Control
VF
Control Mode
Settings
 One of the two modes includes a "Line Start Lockout" feature. When line start lockout is
enabled, the motor drive does not run when you apply power. The Line Start Lockout feature
does not guarantee that the motor never starts under this condition. It is possible the motor may
be set in motion by a mechanical vibration or malfunctioning switch.
 This parameter controls operation from external terminals.
Pr.02-01
0, 1
Two-wire operation control (1)
FWD / STOP
REV / STOP
02-02
Torque Check
VF
Control Mode
Settings
 When the drive receives the operation signal, the drive checks if there is a torque output. When
enabled, the drive releases the mechanical brake after confirming that there is a torque output.
Pr.02-00=1
Multi-function
0
output
1
MO= 15
SVC
FOCPG
0: FWD/STOP, REV/STOP
1: FWD/STOP, REV/STOP (Line Start Lockout)
SVC
FOCPG
0: Disable
1: Enable
Chapter 8 Descriptions of Parameter SettingsEB3000
Enable Drive
0
False
False
FOCPM
External Terminal Control Circuits
FOCPM
8-02-3
1
False
True
Default: 0
Default: 0