Delta EB3000 Series User Manual page 210

Elevator drive
Table of Contents

Advertisement

Settings
Functions
32
Middle torque bias
33
Low torque bias
34–37: Reserved
Disable writing to
38
EEPROM
39
Reserved
40
Enable drive function
Magnetic contactor
41
detection
42
Mechanical brake 1
EPS function
(Emergency Power
43
System)
44
Mechanical brake 2
45–51 Direct docking mode only Contact Delta for more information.
Terminal leveling signal
53
for direct docking
54
Power failure signal
Chapter 8 Descriptions of Parameter SettingsEB3000
31
32
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
When enabled, you cannot write to EEPROM.
Reserved
When enabled, it executes the motor drive function. This function can be
used with multi-function output (setting Pr.01-10–Pr.01-13 to 15) and
(Pr.03-02 and Pr.03-03).
This terminal is for the magnetic contactor feedback signal ON/OFF.
When the motor drive receives a RUN command, it enables the
corresponding output terminal (setting 15) after Pr.03-02 time. It checks if
this function is enabled in the detection time (Pr.04-12). If NOT, the
magnetic contactor error occurs and error code "MCF" displays.
When the motor drive receives a RUN command, it enables the
corresponding output terminal (setting 12) after Pr.03-00 time. It checks if
this function is enabled in the detection time (Pr.04-11). If NOT, the
mechanical brake error occurs and error code "MBF" displays.
If power is cut during running, the drive stops when the DC bus voltage is
less than the low voltage level. After power is cut, the drive runs
according to the EPS frequency when EPS is applied and this function is
ON.
When the motor drive receives a RUN command, it enables the
corresponding output terminal (setting 12) after Pr.03-00 time. It checks if
this function is enabled in the detection time (Pr.04-11). If NOT, the
mechanical brake error occurs and error code "MBF" displays.
When the elevator runs to the leveling area, controller sends a signal to
the drive to make the drive stop within effective distance (Pr.02-53).
When power failure occurs, the host controller inputs this signal to inform
the drive. When the motor drive receives this signal, MO = 49 is disabled
after Pr.02-28 time
8-01-5
Descriptions
33
Torque Bias
OFF
N/A
ON
Pr.02-45
OFF
Pr.02-44
ON
Pr.02-44+ Pr.02-45
OFF
Pr.02-43
ON
Pr.02-43 + Pr.02-45
OFF
Pr.02-43 + Pr.02-44
ON
Pr.02-43 + Pr.02-44 + Pr.02-45