Delta EB3000 Series User Manual page 147

Elevator drive
Table of Contents

Advertisement

Chapter 7 Summary of Parameter SettingsEB3000
01 Input / Output Parameters
Pr.
Parameter Name
Multi-function Input
 01-00
Command 1 (MI1)
Multi-function Input
 01-01
Command 2 (MI2)
Multi-function Input
 01-02
Command 3 (MI3)
Multi-function Input
 01-03
Command 4 (MI4)
Multi-function Input
 01-04
Command 5 (MI5)
Multi-function Input
 01-05
Command 6 (MI6)
Multi-function Input
 01-06
Command 7 (MI7)
Multi-function Input
 01-07
Command 8 (MI8)
Setting Range
0: No function
1: Multi-step speed command 1
2: Multi-step speed command 2
3: Multi-step speed command 3
4: Multi-step speed command 4
5: Reset
6: JOG command
7: Acceleration/deceleration speed inhibit
8: First, second acceleration/deceleration
time
9: Third, fourth acceleration/deceleration
time
10: EF input (Pr.02-16)
11: Reserved
12: Stop output
13–14: Reserved
15: AUI1 operation speed command
16: Reserved
17: AUI2 operation speed command
18: Emergency Stop (Pr.02-16)
19–23: Reserved
24: FWD JOG Command
25: REV JOG Command
26: Reserved
27: ASR1/ASR2 selection
28: Emergency stop (EF1) (motor coasts
to stop)
29–30: Reserved
31: High torque bias (according to Pr.02-
43)
32: Middle torque bias (according to
Pr.02-44)
33: Low torque bias (according to Pr.02-
45)
34–37: Reserved
38: Disable writing to EEPROM
39: Reserved
7-6
Default
1
2
3
4
0
0
0
40

Advertisement

Table of Contents
loading

Table of Contents