Delta EB3000 Series User Manual page 336

Elevator drive
Table of Contents

Advertisement

Abbreviated
ID No.
Warning Code
3
CE03
Action condition
Action time
Warning treatment
parameter
Reset method
Reset condition
Record
Cause
Incorrect communication
command from elevator
controller
Malfunction caused by
interference
Different communication
setting from the elevator
controller
Disconnection or bad
connection of the cable
Abbreviated
ID No.
Warning Code
4
CE04
Action condition
Action time
Warning treatment
parameter
Reset method
Reset condition
Record
Cause
Incorrect communication
command from elevator
controller
Malfunction caused by
interference
Different communication
setting from the elevator
controller
Disconnection or bad
connection of the cable
Display on
Warning Name
KPED-LE02
Communication error 3
Action and Reset
When the length of communication data is too long
Immediately act
Pr.04-60 (Default: 3)
0: Warn and keep operation
1: Fault and ramp to stop
2: Reserved
3: No action and no display
Auto
When Pr.04-60=0, cE03 is a warning and will be automatically cleared.
Manual When Pr.04-60=1, cE03 is a fault and must be reset manually.
N/A
If cE03 is a warning, it will not be recorded.
If cE03 is a fault, it will be recorded.
Check if the communication command is correct.
Verify the wiring and grounding of the communication circuit. It is recommended to
separate the communication circuit from the main circuit, or wire in 90 degree for
effective anti-interference performance.
Check if the setting for Pr.09-00–Pr.09-02 is the same as the setting for the elevator
controller.
Check the cable and replace it if necessary.
Display on
Warning Name
KPED-LE02
Communication error 4
Action and Reset
N/A
Immediately act
Pr.04-60 (Default: 3)
0: Warn and keep operation
1: Fault and ramp to stop
2: Reserved
3: No action and no display
Auto
When Pr.04-60=0, cE04 is a warning and will be automatically cleared.
Manual When Pr.04-60=1, cE04 is a fault and must be reset manually.
N/A
If cE04 is a warning, it will not be recorded.
If cE04 is a fault, it will be recorded.
Check if the communication command is correct.
Verify the wiring and grounding of the communication circuit. It is recommended to
separate the communication circuit from the main circuit, or wire in 90 degree for
effective anti-interference performance.
Check if the setting for Pr.09-00–Pr.09-02 is the same as the setting for the elevator
controller.
Check the cable and replace it if necessary.
Chapter 9 Warning and Fault CodesEB3000
Illegal data value. Occurs when communication
data length exceeds limits.
Corrective Actions
Data is written to read-only address. Error
occurs when trying to write values into read-
only address such as 0x21xx, 0x22xx, and so
on.
Corrective Actions
9-5
Description
Description
<Go to
List of Warning
Codes>

Advertisement

Table of Contents
loading

Table of Contents