– Loosen the hoses with the Coolant Recirculation Pump - V50-
-E- from the vehicle.
– Mark the arrangement of the coolant hoses -D- (supply to
heater core) and -C- (supply from engine).
– Clamp off the coolant hose to the heater core -B- (for example,
using Hose Clamps - Up To 25 mm - 3094- ).
– Disconnect the connector -A- from the Coolant Recirculation
Pump - V50- .
– Remove the bolts -F- and -G-.
– Clamp off the coolant hose (from engine) -C- (for example,
using Hose Clamps - Up To 25 mm - 3094- ).
Note
If the coolant hose -C- (different versions) should be too short
to clamp, seal it, for example, using a sealing plug after dis‐
connecting.
This illustration shows the hoses on a vehicle without a rear
A/C unit (without a parking heater, auxiliary heater and Cool‐
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
ant Shut-Off Valve - N82- ).
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
– Disconnect the coolant hoses -C- and -D- from Coolant Re‐
circulation Pump - V50- .
– Remove the Coolant Recirculation Pump - V50- -E-.
Installing
Install in reverse order of removal. Note the following:
Note
With a discharged coolant circuit, a new Coolant Recirculation
Pump - V50- -E- may only be operated only after the coolant
circuit has been charged. The dry-running of a new pump may
destroy it.
Since only a small amount of coolant flowed out of the coolant
circuit when removing the Coolant Recirculation Pump - V50-
-E- as described above, the coolant flows immediately into
Coolant Recirculation Pump - V50- after installing and remov‐
ing the hose clamps, and there is no danger of dry-running the
pump.
– Connect 2-pin harness connector -A- to pump only after re‐
moving the hose clamps.
– Re-install the remaining removed components.
– Bleed the coolant circuit. Refer to
⇒ "7 Coolant Circuit, Bleeding", page 78
– Add coolant, if necessary. Refer to ⇒ Engine Mechanical;
Rep. Gr. 19 ; Coolant System .
6.5
Coolant Shut-Off Valve - N82- , Remov‐
ing and Installing
Special tools and workshop equipment required
♦ Hose Clamps - Up To 25 mm - 3094-
Heating, Ventilation and Air Conditioning - Edition 04.2013
with respect to the correctness of information in this document. Copyright by AUDI AG.
.
6. Incorporation of the A/C System in Vehicle Coolant Circuit
Audi Q7 2007 ➤
75

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents