Audi Q7 2007 Repair Manual page 272

Heating, ventilation and air conditioning
Hide thumbs Also See for Q7 2007:
Table of Contents

Advertisement

Audi Q7 2007 ➤
Heating, Ventilation and Air Conditioning - Edition 04.2013
– Unscrew the cover -A- and remove it with seal -B-.
WARNING
♦ Refrigerant must be extracted from refrigerant circuit be‐
fore removing sealing cap -D-. If the circlip -C- and sealing
cap -D- are not removed within 10 minutes after extraction,
pressure may build up in refrigerant circuit by renewed
evaporation. Extract the refrigerant once more.
– Check the refrigerant circuit pressure using, for example, a
pressure gauge from the A/C service station. Refer to ⇒ A/C
System with Refrigerant R134a; Rep. Gr. 87 ; Refrigerant Cir‐
cuit (A/C System with Refrigerant R134a; Refrigerant Circuit,
Using Service Station).
WARNING
Only remove the circlip -C- when pressure in refrigerant circuit
is the same or less than the ambient pressure.
– Press. Press sealing cap -D- into the receiver/dryer in the di‐
rection of the -arrow-
Note
The sealing cap -A- is sealed by two O-ring seals -C- in the re‐
ceiver/dryer, if these O-ring seals should be dried out during
operating time, sealing cap -A- can only be pressed into receiver/
dryer and then removed with difficulty, if necessary clean inside
of receiver/dryer -B- and then coat it lightly with refrigerant oil.
– Loosen the circlip -C- and remove it
– Screw in one cylinder bolt (with a M5 thread at this time) into
thread of sealing cap -D- and pull out sealing cap -D- using
pliers on the bolt.
266
Rep. Gr.87 - Air Conditioning
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.

Hide quick links: