Vent Frame, Checking

– Check for blockage of the air ducts between the vent grilles
-C- of the luggage compartment lining (left and right) and the
two vent frames -A-.
♦ Sealing lips -B- in ventilation frames -A- must move freely and
close by themselves.
♦ Blocked channels or jammed sealing lips may cause windows
to fog up.
Note
In this illustration, ventilation frame is depicted with rear bump‐
er removed.
One vent frame is installed on left and right for forced air ex‐
traction.
To ensure that sealing lips -B- close correctly, ventilation
frame -A- must be installed on the correct side.
For the passenger compartment ventilation system to function
properly, the channels worked in behind the left and right lug‐
gage compartment lining to air duct to ventilation frame -A-
and both ventilation grates -C- must not be blocked.