Audi Q7 2007 Repair Manual page 208

Heating, ventilation and air conditioning
Hide thumbs Also See for Q7 2007:
Table of Contents

Advertisement

Audi Q7 2007 ➤
Heating, Ventilation and Air Conditioning - Edition 04.2013
Note
If the evaporator in rear A/C unit is to be cleaned in its own work
procedure, place the outlet hose of Ultrasound A/C Cleaner -
VAS6189A- during the second work procedure in such a way that
the steam emitted is drawn in via air grate in left side luggage
compartment lining.
– Close vehicle doors.
Note
The cleaning procedure lasts approximately 15 to 20 minutes, it
is complete when vapor no longer escapes from outlet hose of
Ultrasound A/C Cleaner - VAS6189A- .
Final Procedures
– Turn the Ultrasound A/C Cleaner - VAS6189A- off.
– Open vehicle doors and air out vehicle at least ten minutes.
– Remove the Ultrasound A/C Cleaner - VAS6189A- from vehi‐
cle and clean it according to operating instructions.
– Switch off ignition.
– Install dust and pollen filter. Refer to
⇒ "9.35 Dust and Pollen Filter, Removing and Installing", page
169
.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
202
Rep. Gr.87 - Air Conditioning