– Repeat cooling performance test. Refer to
⇒ "13 A/C Unit, Checking Cooling Output", page 215
– Observe the display with the refrigerant circuit pressure and the activation of the A/C Compressor Reg‐
ulator Valve - N280- during the cooling output test. Did the valve -N280- activation shut off during the
cooling output test (the control current was less than 0.50 A)?
– Check DTC memory of A/C system, repair malfunctions
displayed and erase DTC memory. Use the Vehicle Di‐
agnostic Tester via the "Guided Fault Finding" function.
– Read the compressor shut-off condition and correct the
cause for the shut-off. Use the Vehicle Diagnostic Test‐
er via the "Guided Fault Finding" function.
Repeat the cooling output test.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Continuation of test "Pressure in refrigerant circuit increases"
– Open hood.
– Repeat cooling performance test. Refer to
⇒ "13 A/C Unit, Checking Cooling Output", page 215
Do(es) Coolant Fan(s) - V7- run during cooling performance test (speed depends on coolant temperature
and pressure in refrigerant circuit, speed is determined by engine control module)?
– Read the pressure in the refrigerant circuit and the cool‐
ant fan activation in the measured value block. Use the
Vehicle Diagnostic Tester via the "Guided Fault Finding"
function.
♦ Does the Coolant Fan - V7- operate according to display
(run at increased speed when pressure in refrigerant
circuit increases)?
Yes
Heating, Ventilation and Air Conditioning - Edition 04.2013
Yes
Yes
No
.
Did the pressure in refrigerant circuit in‐
crease during cooling performance test?
Yes
Continuation of test
⇒ page 225
(Pressure
in refrigerant circuit in‐
creases)
.
– Check the activation of the Coolant Fan -
V7- , for example in function "output Diag‐
nostic Test Mode (DTM)". Use the Vehicle
Diagnostic Tester via the "Guided Fault Find‐
ing" function.
– Repair the activation of Coolant Fan - V7- .
– Repeat cooling performance test. Refer to
⇒ "13 A/C Unit, Checking Cooling Output",
page 215
.
13. A/C Unit, Checking Cooling Output
Audi Q7 2007 ➤
No
No
– Bring the vehicle to
a workshop that has
the necessary tools
and in which the
work can be per‐
formed accordingly
by qualified person‐
nel (notify the work‐
shop about the mal‐
function). Refer to
⇒ Refrigerant
R134a Servicing;
Rep. Gr. 87 ; A/C
System General In‐
formation (Refriger‐
ant R134a, Servic‐
ing; A/C System,
General Informa‐
tion).
No
225