Determining Malfunction During Temperature Increase Downstream Of Evaporator In Front A/C Unit - Audi Q7 2007 Repair Manual

Heating, ventilation and air conditioning
Hide thumbs Also See for Q7 2007:
Table of Contents

Advertisement

13.2.5
Determining Malfunction during Tem‐
perature Increase Downstream of Evap‐
orator in Front A/C Unit
– Clamp off both coolant hoses from engine to A/C unit (for ex‐
ample, Hose clamps up to 25 mm Diameter - 3094- in left front
wheel housing). Refer to
⇒ "6 Incorporation of the A/C System in Vehicle Coolant Cir‐
cuit", page 66
.
– Repeat cooling performance test. Refer to
⇒ "13 A/C Unit, Checking Cooling Output", page 215
♦ The measured value from both the left -G385- and right -G386- front upper body vent temperature sensor
(or the temperature of the air coming out of the vents in the instrument panel measured with a thermom‐
eter) differs less than 5° C from the measured value from the Evaporator Vent Temperature Sensor -
G263- . Use the Vehicle Diagnostic Tester via the "Guided Fault Finding" function.
Remove the hose clamps using the Hose Clamps - Up To 25
mm - 3094- at both coolant hoses.
Check the activation of the Left Temperature Door Motor -
V158- and of the Right Temperature Door Motor - V159- .
♦ Is the activation of Left Temperature Door Motor - V158- and of
Right Temperature Door Motor - V159- OK?
No
Repair the cause of malfunction.
Use the Vehicle Diagnostic
Tester via the "Guided Fault
Finding" function.
Refer to Wiring diagrams, Trouble‐
shooting & Component locations.
Repeat cooling performance
test. Refer to
⇒ "13 A/C Unit, Checking Cool‐
ing Output", page 215
Heating, Ventilation and Air Conditioning - Edition 04.2013
Yes
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Yes
Check the operation of Left Temperature Door Motor - V158-
⇒ "9.9 Retaining plate with Left Footwell Door Motor V108 and Left
Temperature Door Motor V158 , Removing and Installing",
page 114
and of Right Temperature Door Motor - V159- . Refer to
⇒ "9.23 Retaining Plate with Control Motors V158 ( V159 ) and V109
( V108 ), Removing and Installing", page 153
Is the functionality of the Left Temperature door Motor - V158- and
of Right Temperature door Motor - V159- and door operation OK?
Yes
.
Check function of respec‐
tive temperature door in
the A/C unit, for example
with the control motor re‐
moved.
Repeat cooling performance test. Refer to
⇒ "13 A/C Unit, Checking Cooling Output", page 215
.
Check the correct installation of
sender with measured value devia‐
tion, as well as checking electrical
connections for contact resistance.
♦ On vehicles with "Basic" version A/C
system, only the measured value of
Evaporator Vent Temperature Sen‐
sor - G263- can be checked.
Eliminate cause of incorrect meas‐
ured value, replace defective send‐
Repair the door actuation mecha‐
13. A/C Unit, Checking Cooling Output
Audi Q7 2007 ➤
No
er.
.
No
nism.
Refer to
.
.