Rear Condensation Water Drain, Checking, Removing And Installing - Audi Q7 2007 Repair Manual

Heating, ventilation and air conditioning
Hide thumbs Also See for Q7 2007:
Table of Contents

Advertisement

Audi Q7 2007 ➤
Heating, Ventilation and Air Conditioning - Edition 04.2013
– Remove the right front seat (front passenger's seat) complete‐
ly with lower seat frame. Refer to ⇒ Body Interior; Rep. Gr.
72 .
– Carefully fold the rear floor carpet in the center console area
aside. Refer to ⇒ Body Interior; Rep. Gr. 70 ; Trim; Rear Floor
Covering, Removing and Installing .
– Remove the bolts -A-.
– Disconnect the connector from the Right B-Pillar/Footwell
Shut-Off Door Motor - V211- -B- and remove the control motor
-C- with the cover -D-.
– Disengage the connecting rod -E- from the control motor lever
-F-.
Installing
– Check that the connecting rod -E- is installed on proper side.
– Install the removed components again in reverse order.
– Check DTC memory of the Climatronic Control Module - J255-
front A/C control head (and of Rear A/C Display Control Head
- E265- ) and erase any DTCs displayed. Use the Vehicle Di‐
agnostic Tester via the "Guided Fault Finding" function.
– If necessary, perform a basic setting and output diagnostic test
mode on the A/C system. Use the Vehicle Diagnostic Tester
via the "Guided Fault Finding" function.
9.54
Rear Condensation Water Drain,
Checking, Removing And Installing
Note
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
The condensation water drain is installed in area of left rear fender
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
and can be checked from outside without having to remove the
with respect to the correctness of information in this document. Copyright by AUDI AG.
components for it.
Checking
– Check valve -A- from below (with vehicle on a lift). Valve must
not be obstructed by wax or underbody sealer and must close
properly.
– Check condensation water drain of rear A/C unit -F- for soiling
(for example, using a piece of wire) and clean it if necessary.
Note
Condensation water hose -D- must fit securely on connection
of the A/C unit -F-.
Condensation water hose -D- to valve -A- must not be kinked
or pinched.
Depending on production time period, the condensation drain
hose -D- is secured by a hose clamp -E- or a cable tie to con‐
densation water drain of rear A/C unit -F-.
Removing
– Switch off ignition.
196
Rep. Gr.87 - Air Conditioning

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents