Main Circuit And Motor Connections - Omron R88M-1M Series User Manual

Ac servomotors/servo drives
Hide thumbs Also See for R88M-1M Series:
Table of Contents

Advertisement

3 Specifications
3-1-4

Main Circuit and Motor Connections

When you wire the main circuit, use proper wire sizes, grounding systems, and noise resistance.
R88D-1SN01L-ECT/-1SN02L-ECT/-1SN04L-ECT/-1SN01H-ECT
/-1SN02H-ECT/-1SN04H-ECT/-1SN08H-ECT/-1SN10H-ECT
 Main Circuit Connector (CNA) Specifications
Pin No.
Symbol
1
L1
2
L2
3
L3
4
B3
5
B2
6
P/B1
7
N1
8
N2
9
N3
10
24V
11
*1. For single-phase, connect between any two phases out of the following: L1, L2, and L3.
*2. Internal regeneration resistor is not built in the following product models.
Applicable models: R88D-1SN01L-ECT, R88D-1SN02L-ECT, R88D-1SN01H-ECT, R88D-1SN02H-ECT,
R88D-1SN04H-ECT
1
3 - 14
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User's Manual (I586)
Name
Main circuit power sup-
R88D-1SNL-ECT
ply input
Single-phase
to 63 Hz)
R88D-1SNH-ECT
Single-phase
to 63 Hz)
R88D-1SNH-ECT
3-phase 200 to 240 VAC (170 to 252 V) 50/60 Hz (47.5 to 63
Hz)
External Regeneration
When the Internal Regeneration Resistor is used
Resistor connection ter-
• Open between B1 and B2.
minals
• Short-circuit B2 and B3.
When the External Regeneration Resistor is used:
• Connect the External Regeneration Resistor between B1
• Open between B2 and B3.
DC reactor connection
When the DC reactor is not used:
terminals
• Short-circuit N1 and N2.
When the DC reactor is used:
• Connect the DC reactor between N1 and N2.
Control circuit power
24 VDC (21.6 to 26.4 V)
supply input
Measured current value: 600 mA
Specifications
*1
100 to 120 VAC (85 to 132 V) 50/60 Hz (47.5
*1
200 to 240 VAC (170 to 252 V) 50/60 Hz (47.5
and B2.
11
*2
:

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88m-1l seriesR88d-1sn ect seriesR88d-1sn01l-ectR88d-1sn02l-ectR88d-1sn04l-ectR88d-1sn01h-ect ... Show all

Table of Contents