Select the IP address and model name
of the PMAC to use.
For the revision, select 1.
When you finished entering the data,
click the Add button.
In this document, the default PMAC
address (192.168.0.200) is used.
3-2-7

Setting EtherNet/IP (Connections)

1
Click the Connection icon.
2
Setting Connection 1
Next, click the + icon.
For the added row, set the items as fol-
lows.
Target Device: PMAC to use
Connection I/O Type: Exclusive Owner
1
RPI: 50.0 ms
Target Variable: 768 for inputs and 769
for outputs
Size: 504
Originator Variable:
eip_from_ppmac_01, eip_to_ppmac_01
CK3E/CK3M/CK5M Series EtherNet/IP Connection Guide (O903)
*1
3 EtherNet/IP Connection Procedures
3
3-11