Surge Absorber
• Use a surge absorber to absorb the lightning surge voltage and the abnormal voltage from the power
input line.
• The following table gives the recommended surge absorber specifications.
Servo Drive voltage
Single-phase 100 VAC
Single-phase 200 VAC
3-phase 200 VAC
3-phase 400 VAC
Note 1. Refer to the catalogs from the manufacturer for how to use.
2. The surge current tolerance is the value for the standard impulse current of 8/20 μs. For a greater pulse
width, reduce the current or change the surge absorber to the one with a higher capacity.
3. Select a CSA-certified product when you use a surge absorber.
 External Dimensions
For single-phase
Separator
operation indicator
19
Lead wire (L3)
38
 Equivalent Circuit
For single-phase
4 - 66
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User's Manual (I586)
Surge current tolerance
410 V±20%, 2500 A
410 V±20%, 2500 A
410 V±20%, 2500 A
800 V±20%, 2500 A
Lead wire (L1)
Ground wire
Case
22.5
Thermal fuse
ZnO element
Discharging gap
Recommended
manufacturer
Soshin Electric Co., Ltd.
Soshin Electric Co., Ltd.
Soshin Electric Co., Ltd.
Soshin Electric Co., Ltd.
For 3-phase
Separator
operation indicator
19
Lead wire (L3)
Lead wire (L2)
38
For 3-phase
Thermal fuse
ZnO element
Discharging gap
Recommended model
LT-C12G801WS
LT-C12G801WS
LT-C32G801WS
LT-C35G102WS