Specifications Of External Regeneration Resistors And External Regeneration Resistance Units; General Specifications; Regeneration Resistance Units - Omron R88M-1M Series User Manual

Ac servomotors/servo drives
Hide thumbs Also See for R88M-1M Series:
Table of Contents

Advertisement

3-5
Specifications of External
Regeneration Resistors and External

Regeneration Resistance Units

This section describes the specifications of the External Regeneration Resistor and External Regener-
ation Resistance Unit.
Refer to 2-4-6 Dimensions of External Regeneration Resistors and External Regeneration Resistance
Units on page 2-119 for external dimensions.
3-5-1

General Specifications

Item
Dielectric strength
Insulation resistance
Operating ambient tempera-
ture and humidity
Storage ambient temperature
and humidity
Operating and storage atmo-
sphere
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User's Manual (I586)
R88A-RR120/-RR300
Between terminals and case: 2,000 VAC for 1 min (at 50/60 Hz)
Between terminals and case: 20 MΩ min. (at 500 VDC)
0 to 55°C, 90% max.
(with no condensation)
-25 to 85°C, 95% max.
(with no condensation)
No corrosive gases
3 Specifications
Model
R88A-RR1K6/-RR550
0 to 55°C, 90% max.
(with no condensation)
-20 to 65°C, 90% max.
(with no condensation)
3
3 - 127

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88m-1l seriesR88d-1sn ect seriesR88d-1sn01l-ectR88d-1sn02l-ectR88d-1sn04l-ectR88d-1sn01h-ect ... Show all