9 Details on Servo Parameters
Subindex 03 hex: Capacitor Discharge Enable
• Selects whether to enable or disable the capacitor discharge enable function.
• When the function is enabled, the electric charge in the capacitor is discharged through the internal
or external regeneration resistor by turning the main circuit power supply OFF while the control power
supply is ON.
 Description of Set Values
Set value
0
1
Subindex 81 hex: P-N Voltage
• Gives the P-N voltage.
Subindex 82 hex: Servo Drive Temperature
• Gives the internal temperature of the Servo Drive.
9 - 100