Omron R88M-1M Series User Manual page 794

Ac servomotors/servo drives
Hide thumbs Also See for R88M-1M Series:
Table of Contents

Advertisement

Appendices
Index
Subindex
(hex)
(hex)
609A
00
607C
00
60FC
00
6062
00
Controlword (6040 hex) in Homing Mode
Bit
4
Homing operation start
8
Halt
*1. A Command Warning (Error No. B1.00) will occur if the Homing operation start command is given while the
homing procedure is performed.
Bit 6 is not used. For details on other bits, refer to Controlword (6040 hex).
Statusword (6041 hex) in Homing Mode
Bit
10
Target reached
12
Homing attained
13
Homing error
Bit 13
Bit 12
0
0
0
0
1
1
1
1
A - 8
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User's Manual (I586)
Name
Access
Homing accelera-
RW
tion
Home offset
RW
Position demand
RO
internal value
Position demand
RO
value
Name
Value
0
1
0
1
Name
Bit 10
0
0
Homing procedure is in progress.
0
1
Homing procedure is interrupted or not started.
1
0
Homing is attained, but target is not reached.
1
1
Homing procedure is completed successfully.
0
0
Homing error occurred, velocity is not 0.
0
1
Homing error occurred, velocity is 0.
1
0
Reserved
1
1
Reserved
Size
Unit
U32
Command
2
unit/s
INT32
Command unit
INT32
Encoder unit
INT32
Command unit
Do not start homing procedure.
Start or continue homing procedure.
Enable bit 4.
Stop axis according to the Halt option code (605D hex).
Description
The status of the homing operation is indicated by the combination
of these bits.
The status based on the combination of the bits are shown in the
following table.
Description
Setting range
1 to 2,147,483,647
1,000,000
-2,147,483,648 to
2,147,483,647
---
---
Description
*1
Default
setting
0
---
---