4-1-5
Footprint-type Noise Filter Installation Conditions
Satisfy the space conditions around Servo Drives that are described in 4-1-1 Servo Drive Installation
Conditions on page 4-2.
Use the attached exclusive screws when you mount the Servo Drive to the Noise Filter. The tightening
torque for the exclusive screws is 1.2 N·m±10%.
Mounting Direction
Install the Noise Filter on the vertical metal surface.
Turn the LINE side of Noise Filter in the gravity direction (downward) as shown in the following figure.
Servo Drive
*1. Power supply side
*2. The specifications of the lead wires are shown below.
Noise filter model
R88A-FI1S103/-FI1S105/
-FI1S202/-FI1S203
R88A-FI1S109/-FI1S208
R88A-FI1S116/-FI1S216
R88A-FI1S309
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User's Manual (I586)
Lead wire
Metal plate
Noise filter
Side view
Wire size
AWG 16
AWG 14
AWG 10
AWG 12
4 Configuration and Wiring
*2
Gravity
direction
*1
LINE
Length
Approx. 300 mm
Approx. 300 mm
Approx. 300 mm
Approx. 300 mm
4
Strip length
8.5±0.5 mm
8.5±0.5 mm
13.7±0.5 mm
13.7±0.5 mm
4 - 15